P330Z3 Cooled AD Module for Optical Gas Imaging System

Place of Origin WUHAN
Brand Name GUIDE INFRARED
Certification RoHS2.0
Model Number P330Z3
Minimum Order Quantity 1
Price Negotiable
Payment Terms T/T

Contact me for free samples and coupons.

WhatsApp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Resolution 320×256/30μm Spectral Response MW 3.2±0.1μm~3.5μm±0.1μm
Frame Rate 1~200Hz (Default 30Hz) Working Temperature -40~+60℃
Highlight

Gas Imaging System Cooled AD Module

,

Optical Gas Imaging Cooled AD Module

,

Imaging System Integration Cooled AD Module

Leave a Message
Product Description

Product Description:

The P330Z3 cooled AD modules for optical gas imaging adopt high-performance signal processing circuits to realize the conversion of analog signal to digital signal. It is an accelerator for integrators who have difficulty in starting fast optical gas imaging system integration.

By utilizing the infrared technology, the invisible methane and other volatile organic compounds (VOCs) leaks could be quickly and effectively detected to ensure the safety in production, transportation and processing of petrochemical enterprises.

Main Features:

Accelerate development speed
• With high-performance signal processing circuits
• Digitization of detector drive and analog signal

Easy to develop & integrate
• Cameralink interface output 16bit raw data, serial port control
• Integrated structural design that has consistent dimension with detector

Technical Parameters:

Model P330Z3
Resolution 320*256
Pixel Size 30μm
Cryo Cooler RC3
Spectral Response 3.2μm±0.1μm~3.5μm±0.1μm
Cooling Time (25℃) ≤6.5min
NETD (25℃) 10mK (F1.5)
Frame Rate (Adjustable) 1~200Hz (Default 30Hz)
Working Mode Snapshot;  
ITR Integration Mode;
Windows Mode;
Anti-blooming
Standard External Interface QSH60
Digital Video Cameralink: Output 16bit Raw Data
External Sync CC1: INT/Frame External Sync
CC2: MC External Sync
Communication Cameralink Serial Port: TFG+/-, TC+/-; 9600bps
Power Supply Channel 1 (Imaging Panel): 5V
Channel 1 (Cryocooler): 12V
Steady Power Consumption 7W
Size (mm) 142*58.5*71
Weight ≤650g
Working Temperature -40°C ~ +60°C

Applications:

P330Z3 Cooled AD Module for Optical Gas Imaging System 0

Technical Support:

We believe that technical support should not only resolve customer issues but also assist clients in building their own technical maintenance teams. Through effective technical support, we aim to empower our customers' maintenance personnel by sharing valuable experiences and knowledge. This collaborative approach ultimately helps us achieve our primary goal: ensuring customer satisfaction and fostering long-term partnerships.

Additionally, we provide technical training to help customers better utilize our products and improve their skills and knowledge. Through these measures, we aim to enhance the customer experience and establish long-term collaborative relationships.

By investing in comprehensive technical support, we strive to enhance our customers' operational efficiency and reliability, thereby solidifying our standing in the industry.

FAQs:

Q: What is infrared thermal imaging technology?

A: Infrared thermal imaging uses photoelectric technology to detect specific infrared band signals of thermal radiation from objects, converts these signals into images and graphics that can be visually distinguished by humans, and further calculates temperature values.

Q: What is the wavelength range for infrared thermal imaging?

A: Infrared ray, also known as infrared radiation, is an electromagnetic wave in the infrared wavelength range between visible light and microwave. Thermal infrared imaging typically refers to mid infrared imaging at 3-5μm and far-infrared imaging at 8-12μm. In these bands, the focus is on heat sources, not visible light. The human eye is sensitive to the wavelength range of about 0.4~0.7μm and cannot see longer wavelengths of thermal energy.

Q: What is the classification of infrared thermal imaging wavebands?

A: Generally speaking, infrared thermal imaging is divided into three bands: short wave, medium wave, and long wave.
Shortwave: wavelength range within 3μm;
Medium wave: wavelength range from 3μm to 5μm;
Long wave: wavelength range from 8μm to 14μm;

Q: What are the applications of infrared detectors and thermal imaging modules?

A: The infrared detectors and thermal imaging modules can be used in a variety of applications such as thermography, security & surveillance, intelligent industry, outdoor night vision observation, machine vision, smart driving, UAVs, and consumer infrared products.

Q: Does infrared thermal imaging emit radiation?

A: Infrared thermal imaging passively receives infrared signals emitted by objects and does not have radiation. As long as an object exceeds absolute zero, an infrared signal will be emitted, which is received by an infrared detector and then converted into a thermal image.